Hi everyone,

I've encountered this annoying issue so many times before, if any one also encounter this issue, please share here if you have any solution.

So, I've been working on a web service project using HealthShare 2015. Sometimes I have to set a debug target to a csp file to debug it. If I pause the debug process about 3 minutes above or so (to examine an object, variable, etc..) the studio will hang.

0 4
0 499

Hello,

I have a little problem that appears to my newest program. One of the purpose of my program is to transfer a file from a path to another one.

Another person/entity places the file into a specific file ( let's call it \\Server\) but the problem is that my service (a simple EnsLib.File.PassthroughService) takes it and places it directly into my other path. The pdf file is very big and it happens almost all the time that the size of the output file is not the same as in input and so is corrupted.

0 3
0 351

Off the back of the Interface Monitoring post I had created a class that queries the Ens.AlertRequest global and returns the entries between 6pm the night before and 6am in the morning.

I tested this build in our T&D environments and the build worked very well.

However in our production environment the query is being truncated, by what I believe to be a timeout and I get a partial query output.

In the System>SQL pages my 12 hour query times out.

0 5
0 236

the file being created on the FTP server will have a format that includes the current date I would like to pull this file off the FTP while ignoring other files on the same location.

Inbound Service Class

I would like to find the file on the FTP that is being created using Todays date. But it appears that the wildcard are not recognizing the file format:

0 5
1 348

I am under the impression that inside HealthShare you can Services, Processes, and Operations. The service takes incoming data, the processes can process that data, and then the operations can send that data out.

I am curious if anyone has any experience, guides, or advice on how I can send data to a service using a Java application. I intend for the data to be in XML format. I am also curious if I succeed at picking up the data in the service, how I send the data back to the Java application using an Operation.

0 2
0 349

In time for InterSystems Global Summit 2019 we at George James Software are pleased to offer a cloud-hosted evaluation environment where you can work with Serenji in Visual Studio Code, editing and debugging ObjectScript in a sandbox running InterSystems IRIS 2019.3 Community edition.

You can do it all from your web browser. Nothing will be installed on your workstation, nor will any settings have to be changed on it.

To take Serenji for a test drive please visit https://georgejames.com/dc-gitpod

2 2
1 351

I am currently working on an Upgrade to HealthShare 2019.1.1. As described in the steps once the upgrade was complete to run $system.OBJ.Upgrade(). When I run $system.OBJ.Upgrade() , it is not finding any classes to update. However I am getting an Error 5116 on one of my Productions...

Class dictionary version for '%1' is out of date, please run upgrade utility $system.OBJ.Upgrade()

1 5
1 805
Question
· Nov 13, 2019
Keep Alive Packet

does Health Connect have an out of box setting to send some type of "Keep Alive" packet? This is for a TCP connection. I have a vendor that will disconnect from the engine if there is a 2 hour idle time. would like to send something across every hour (if its idle) to prevent the disconnection. I'm assuming this may be something custom that needs to be created, but thought I asked the community first.

0 1
0 579

Hi All,

I'm currently trying to modify the provider portal using Trak to add a new column. Using the column editor to get the column to display on the page is relatively simple, but where I'm running into problems is modifying what will display in the column.

Essentially, it just needs to run a simple "if value in column A is in this list, display x, else display y" which is easy enough to write in ObjectScript, but the ISC documentation is relatively sparse about how to get a specific column to run that bit of code to display what I need it to.

0 1
0 217

InterSystems has corrected several critical defects that can result in data integrity issues. These defects were identified and corrected within a short time, so InterSystems has simplified the upgrade process by consolidating them into a single package. The effects of encountering these defects may not always be visible.

0 1
2 434

I have a cube that lists services, processes, and operations information and wanted to make the names of the items more user-friendly to end users and to use a flag to determine which components would be displayed in the dashboard.

We created another table/cube that has a status flag (1/0) to determine whether we would look at the item, the existing name, and the human-readable name.

What is the best way to reference the data in the new cube from the original cube to use the human-readable name?

Thank you, LG

0 1
0 198

Hi,

What is a Foundation Production and what does it do?

We are currently on HealthShare Health Connect 15.03 and we are starting the process of moving to HealthShare Health Connect 2019.1.

The 2019.1 Installation Guide is pretty clear that it is essential, but I'm having trouble working out exactly what it does?

Leading on from this is what should I call it?

From the installation guide:

0 12
0 967

Hi Community,

I am trying to remove a duplicate OBX from a result, but I am running into some issues. Let me explain.

First I had a OBX where the observation Value had the blood type in it and the following OBX had the result in it.

The clients wants the blood type and the result in one field. therefore I merged / concatenated the observation values of the two OBX's.

I tried removing the OBX:2 but just cant take the whole segment out.

please see examples below

This is the result.

0 4
0 653

I have a scenario where I'm using a EnsLib.File.InboundAdapter to collect files from an external file system. The files require to meet a certain criteria before they are moved to another remote file system. If they don't, I would like them to stay where they are so that they can be collected again when the criteria has changed. I have set the adaptor property DeleteFromServer to false - which is fine - the file stays put in its original location, but the file is never collected again as I receive a "Skipping previously processed file " info

0 3
0 751

Hi all,

is it possible to omit the typical XML header line

<?xml version="1.0" encoding="ISO-8859-1" ?>

when writing an the contents of a EnsLib.EDI.XML.Document using the above mentioned operation. I´ve already digged into the config value Format. It only states that:

C(e) : output an XML header line declaring character encoding e. If e is empty use the encoding defined by the Adapter. If e begins with ! force the output stream's encoding. Note that this will be applied automatically for File Operations configured with a non-UTF-8 Charset

0 2
0 412

InterSystems has corrected a defect that could lead to invalid backups on Windows platforms. The defect causes upgrades to disable the EnableVSSBackup setting. By default, EnableVSSBackup is enabled (value set to 1) and the upgrade sets its value to 0. Windows VSS backups taken with this setting disabled may contain invalid CACHE.DAT files.

This problem is limited to Windows platforms on the following versions:

  • Caché and Ensemble 2018.1.0, 2018.1.1, and 2018.1.2
  • HealthShare Health Connect (HSAP) 15.032 on Core versions 2018.1.0, 2018.1.1, and 2018.1.2
  • HealthShare 2019.1 (Unified Care Record, Patient Index, Health Insight, Personal Community, and Provider Directory) on Core version 2018.1.2
  • HealthShare 2018.1 (Information Exchange, Patient Index, Health Insight, and Personal Community) on Core versions 2018.1.1 or 2018.1.0

The defect only occurs if you are upgrading to a version listed above. Once you have upgraded to an affected version, you must manually enable the setting; otherwise, it will be disabled on future upgrades, even when upgrading to versions containing the correction.

For customers using Windows VSS backups, InterSystems recommends enabling this setting on any 2018.1 instances of Caché or Ensemble. Once you have enabled the setting, future upgrades (including to affected versions) will preserve its value.

0 0
0 228
Question
· Aug 29, 2019
Create multiple dependent Tasks

Is it possible to create a task that will initiate a Business Service that is dependent on the completion of a separate EDI data process?

I have a complex data flow with multiple EDI processes where one process must run and produce one or more files that get deposited in the source folder for the next EDI process. The entire process is currently set up where 2 of the EDI processes execute at a specific time. The problem with that is when a network or server interruption occurs at the time they are supposed to start, it causes a complete failure of the entire process.

0 1