When building a bundle from legacy data, I (and others) wanted to be able to control whether or not the resources were generated with a FHIR Request Method of PUT instead of the hard coded POST. I have extended the two classes responsible for transforming SDA to FHIR in an Interoperability Production to accomodate a setting that lets the user control the Request Method.

4 2
0 195
Question
· Nov 15, 2024
DICOM Extended Negotiation

Is there a way to create and establish DICOM Association with Extended Negotiation?

I have implemented DICOM Query/Retrieve C-FIND, using EnsLib.DICOM.Operation.TCP and EnsLib.DICOM.Process base classes. My application, acting as an SCU, needs to query by Study Date-Time (combined date-time matching) range with timezone query adjustment. For this, I need to use Extended Negotiation.

0 0
0 60

Hello,
Please, we would need your help 🙂:

In a development environment, we have added quite a few presentation contexts to the DICOM configurations (the associations). We would need to find a way to export them from this environment to make it easier for us to import them in PRO (and avoid doing it by hand one by one).

0 2
0 73

Hi Community,

OpenAPI-Client Gen has just released, this is an application to create an IRIS Interoperability Production client from Swagger 2.0 specification.

Instead of the existing tool ^%REST that creates a server-side REST application, OpenAPI-Client Gen creates a complete REST Interoperability Production client template.

Install by ZPM:

8 12
0 1.1K

I have been walking through this with a few team members and as such I thought there might be others out there who could use it, especially if you work with HL7 & Ensemble/HealthConnect/HealthShare and never venture out past the Interoperability section.

5 1
1 468
Article
· Oct 17, 2024 2m read
ORU to MDM with large HL7 v2 messages.

I was working on a DTL but kept getting ERROR #5002... MAXSTRING errors. The problem was that most of the DTL GUI action steps only support the string data type when working with the segments. A %String has a limit of 3,641,144 characters and my OBX5.1 was 5,242,952 characters long as the example provided. Of course PACS admin stated ultra high quality up to and including 4K resolution files were needed, so we could not get the vendor to compress or reformat these files to compressed jpg or something similar.

3 7
1 209

In the past, I've created custom SQL operations, but now I had something trivial to do, so I decided to take EnsLib.SQL.Operation.GenericOperation out for a spin. There's no example in the docs, so it was a little tricky. Here's what I ended up doing:

In my external database, I have 'mytable' with two fields 'id1' and 'id2'. Here are the pertinent Business Operation settings:

1 2
0 99

Hi Team, we are going to deliver a speech on a developer forum where most developers hv not used our tech before but using other database and integration technologies , Pls give us some key points on why they should adopt us and the benefits you can get, especially if you change your tech stack from others to IRIS. Thanks a lot!

2 3
0 174

Is there a difference in outcome between the two screengrabs below?

In both cases, when certain conditions are met, a transformation is called and the output sent on to two targets. In the first case we surmise the transformation is called twice, and the output of the first run sent to the first target, the output of the second run to the second target. In the second case we surmise the transformation is called once, and the output duplicated and sent to the two targets.

1 2
0 227

Hello, I want to create PDF from HTML source. I found pandoc. I installed pandoc on IRIS container image. I created Interoperability production. I have setup REST service to receive HTML file in request body. I call pandoc command pandoc -o output.pdf input.html from a BPL process. I copy output.pdf file stream into response body. I save the response at the source. I get a file named output.pdf but it does not load in Acrobat. I suspect I am doing something wrong with headers (accept-encoding?) or maybe do I need to base64 encode the pdf file to transfer it via REST?

0 7
0 194
Article
· Feb 23, 2024 5m read
Using an Azure bot to access IRIS

I have challenged to create a bot application using Azure Bot that can retrieve and post data to IRIS for Health.

A patient's data has already been registered in the FHIR repository of IRIS for Health.

The patient's MRN is 1001. His name is Taro Yamada. (in Japanese :山田 太郎)

This bot can post new pulse oximeter readings as an observation resource linked to the patient.

13 2
2 407
Question
· Jul 10, 2024
Component registration

When registering the components: I used this command:
"Utils.migrate("/external/src/CoreModel/Python/settings.py)" ;
The error appears: "An error has occurred: iris.cls: error finding class",
I changed with these two lines:
result = subprocess.run(["iop", "-m", "/external/src/CoreModel/Python/settings.py"], stdout=subprocess.PIPE, stderr=subprocess.PIPE, check=True)
subprocess.run(["iop", "-m", "/external/src/CoreModel/Python/settings.py"], stdout=subprocess.DEVNULL, stderr=subprocess.DEVNULL, check=True)

0 2
0 102

Up until recently, I have been toying around with REST/FHIR capabilities but only internally. Now I have a request to make REST API calls outside of our Network.

I am using an RSA 4096 key, because Microsoft Active Directory Services which generates the signed certificate could not handle the Elliptical Key (ECC) when I put the request in.

0 0
0 134

Welcome to the next chapter of my CI/CD series, where we discuss possible approaches toward software development with InterSystems technologies and GitLab.
Today, we continue talking about Interoperability, specifically monitoring your Interoperability deployments. If you haven't yet, set up Alerting for all your Interoperability productions to get alerts about errors and production state in general.

Inactivity Timeout is a setting common to all Interoperability Business Hosts. A business host has an Inactive status after it has not received any messages within the number of seconds specified by the Inactivity Timeout field. The production Monitor Service periodically reviews the status of business services and business operations within the production and marks the item as Inactive if it has not done anything within the Inactivity Timeout period.
The default value is 0 (zero). If this setting is 0, the business host will never be marked Inactive, no matter how long it stands idle.

5 1
0 1.2K

Anyone here know if the Implementation Partner program is still open, and if so, is there anyone we can contact to get more details? I've tried reaching out via the form on the website, I've called and left a message, and then I called and talked to someone a few weeks ago who said they would "forward my info over", but we still haven't heard back from anyone. We just want to get more info on what it entails, but can't seem to get in touch with anybody to talk about it.

1 1