Hello InterSystems Community Members,

I hope you are all doing well. I am currently facing an issue while trying to set up the SNMP subagent functionality for my InterSystems Cache installation.

I am using InterSystems Cache for Windows (AMD64) version 5.2.4 (Build 809_0_9006U). The SNMP subagent functionality requires the iscsnmp.dll dynamic library, which I have been unable to locate in my installation directory.

0 1
0 247

Hello,

Our team is working on building dashboard for internal reference and monitoring.

We would like to have details like Interface Name, Current Status, Last Messages Processed at, IP & Port, Serve/Instance/Production Environment name etc.

If there is any built-in service which we can utilize or any pre-compiled code that we can utilize to build such dashboard.

At this moment want to keep it basic, but moving forward will enhance with more advance features.

Please suggest, any help will be appreciated.

Thanks,

Yash

0 0
0 261

In the Windows Ressource Manager I can observe multiple parallel processes coming from cache.exe with read operations to journaling files.

All except one of these processes have the same reads(Byte/s). The processes point to different journal files and constantly read between 200 and 3000 Bytes/s.

The corresponding process via PID in the management portal of Caché shows the process %SYS.Monitor.Control.1. In 3 days of uptime on the server it has run 181.632.583 commands and modified 32.140.642 globals.

0 2
0 216

My employer set up a web-based HL7 interface monitor dashboard that will display all Ensemble components (Service/Process/Operation) in a Production, their status, and the support information embedded in each interfaces listing on the Monitor. Please see 3 screenshots.

This is part of the URL that we go to when accessing this Web based Monitor: ......57772/csp/healthshare/monitor/Rush.Monitor.Web.Home.cls

0 3
0 222

I'm using the EnumerateJobStatus query of class Ens.Util.Statistics to obtain the LastActivity value of a Business Host.

I would expect that this would return the timestamp of the last message received by the BH, understanding that any connect/disconnect activity would reset that timer. However, the time returned appears to actually be the time at which Ens.MonitorService generated the alert and is not directly related to anything that happened in the BH itself.

0 1
0 171
Article
· Aug 26, 2016 8m read
Enterprise Monitor and HealthShare

Enterprise Monitor is a component of Ensemble and can help organizations monitor multiple productions running on different namespaces within the same instance or namespaces running on multiple instances.

Documentation can be found at:

http://docs.intersystems.com/ens20161/csp/docbook/DocBook.UI.Page.cls?KEY=EMONITOR_all#EMONITOR_enterprise

In Ensemble 2016.1 there were changes made to make this utility work with HealthShare environments.

This article will:

  • Show how to set up Enterprise Monitor for HealthShare sites
  • Show some features of Enterprise Monitor
  • Show some features of Enterprise Message Viewer

For this article, I used the following version of HealthShare:

Cache for Windows (x86-64) 2016.1 (Build 656U) Fri Mar 11 2016 17:42:42 EST [HealthShare Modules:Core:14.02.2415 + Linkage Engine:14.02.2415 + Patient Index:14.02.2415 + Clinical Viewer:14.02.2415 + Active Analytics:14.02.2415]

10 2
0 1.5K

Released with no formal announcement in IRIS preview release 2019.4 is the /api/monitor service exposing IRIS metrics in Prometheus format. Big news for anyone wanting to use IRIS metrics as part of their monitoring and alerting solution. The API is a component of the new IRIS System Alerting and Monitoring (SAM) solution that will be released in an upcoming version of IRIS.

11 2
7 2.1K
Article
· Feb 3, 2023 3m read
Queue monitoring

Overview

With the gradual improvement of hospital information construction, there are more and more business interfaces in hospitals. Due to the influence of various factors (network, consumer system, etc.), the data processing of business interface may cause excessive message accumulation and even the situation of interface card congestion, which affects the normal business development in the hospital. Therefore, the monitoring of the queue of business interface components becomes more and more important.

3 2
0 465
Article
· Feb 7, 2023 3m read
IRIS Queue monitoring component

1. Overview

With more and more hospital applications built, business interface data processing may be affected by a variety of factors (network, consumer systems, etc.), there is an excessive accumulation of messages or even cause interface lag, affecting the routine performance of hospital IT systems , so the monitoring of the business interface components queue is increasingly important.

While current Intersystems IRIS platform's built-in queue monitoring only displays real-time queue information for interface components, which is limited in providing the queue data information needed by hospitals. The queue monitoring component program is based on the Intersystems IRIS platform and can monitor all interface components and display component queue information within 24h of the component, as well as query component historical queue data by setting a time period to better meet the needs of current in-hospital applications.

4 1
0 301

Some Usage cases

1. A deployment may consist of two high availability instances and two disaster recovery instances in a different data center.

The corresponding UAT environment could replicate this giving a total of 8 instances. How do you confirm CPF and Scheduled task alignment across ALL instances.

3 2
0 418

Hello everybody,

In the documentation I read the following:

Alerts are messages generated by production components. InterSystems IRIS automatically writes the alerts to a log file and sends then to the production component named Ens.Alert. If your production does not have a component named Ens.Alert, then InterSystems IRIS writes alerts to the log file but does not send them to any component. The component named Ens.Alert can be of any class. The most frequently used classes for Ens.Alert are:

0 3
1 286

The following steps show you how to display a sample list of metrics available from the /api/monitor service.

In the last post, I gave an overview of the service that exposes IRIS metrics in Prometheus format. The post shows how to set up and run IRIS preview release 2019.4 in a container and then list the metrics.


This post assumes you have Docker installed. If not, go and do that now for your platform :)

18 10
6 1.5K
Article
· Feb 25, 2019 4m read
Using Grafana directly from IRIS

There have been some very helpful articles in the community that show how to use Grafana with IRIS (or Cache/Ensemble) by using an intermediate database.

But I wanted to get at IRIS structures directly. In particular, i wanted to access the Cache History monitor data that is accessible by SQL as described here

https://community.intersystems.com/post/apm-using-cach%C3%A9-history-mon...

and didn't want anything between me and the data.

9 5
4 1.6K

Hello

I have a problem on enabling SNMP monitoring on Cache.

I installed on HP UX NET SNMP 5.7.2 package from HP Software Center and enabled agentX protocol in snmpd.cfg.

When I enabled full debugging on Cache and NET SNMP I discovered that sent and received packets on both sides are not the same. Some bytes are different. I think the problem is in default charset for TCP/IP connection which is on our system set to CP1250 instead of default RAW. So result is that Cache notifies are not visibile from snmpwalk etc.

Is there a solution for this issue?

0 4
0 219

Hello,

I am currently having the experience activating prometheus for iris db.

This environment that I speak uses IKO as a base.

I need to put 3 notes in the iris service area.

Are they:

annotations:
   prometheus.io/path: "/monitor/metrics"
   prometheus.io/port: "52772"
   prometheus.io/scrape: "true"

I'm not finding this possibility in the IKO documentation.

Has anyone had this experience and can help us with this challenge?

0 4
0 262
Article
· Jul 12, 2019 2m read
Basic Database Metrics example

This is a self contained class that can be run from the Intersystems Task Scheduler which records peak usage details for databases and licenses built up throughout the day and retaining 30 days history.

To schedule the task to run every hour:

d ##class(Metrics.Task).Schedule()

You can also specify your own start time, stop time, and run interval:

d ##class(Metrics.Task).Schedule(startTime, stopTime, intervalMins)

Metrics are stored in ^Metrics in the namespace that the class resides in/is run from.

6 3
3 564

Hey Developers,

We're pleased to invite you to join the next InterSystems IRIS 2020.1 Tech Talk: DevOps on June 2nd at 10:00 AM EDT!

In this InterSystems IRIS 2020.1 Tech Talk, we focus on DevOps. We'll talk about InterSystems System Alerting and Monitoring, which offers unified cluster monitoring in a single pane for all your InterSystems IRIS instances. It is built on Prometheus and Grafana, two of the most respected open source offerings available.

Next, we'll dive into the InterSystems Kubernetes Operator, a special controller for Kubernetes that streamlines InterSystems IRIS deployments and management. It's the easiest way to deploy an InterSystems IRIS cluster on-prem or in the Cloud, and we'll show how you can configure mirroring, ECP, sharding and compute nodes, and automate it all.

Finally, we'll discuss how to speed test InterSystems IRIS using the open source Ingestion Speed Test. This tool is available on InterSystems Open Exchange for your own testing and benchmarking.

4 6
1 578

Hi:

Currently we are using an older Healthshare instance but I am not opposed to using IRIS as we will upgrade eventually.

Currently for monitoring productions we have a Montior screen. We have both the Queues page and a Deepsee dashboard which has current status of our services. The issue with the Deepsee method we currently have with traffic lights is 1) the page is a bit slow to load the metrics 2) any new services from the team a new widget needs created and although this is easy enough to do it just is time consuming.

0 5
0 422